Get New 2021 Network Appliance NS0-176 Exam Dumps Bundle On flat Updated Dumps! [Q45-Q69]

Share

Get New 2021 Network Appliance exam NS0-176 Dumps Bundle On flat Updated Dumps!

Full NS0-176 Practice Test and 141 unique questions with explanations waiting just for you, get it now!

NEW QUESTION 45
After deploying a FlexPod solution, which tool would you use to validate a successful installation?

  • A. Config Advisor
  • B. UCS Manager
  • C. Hardware Universe
  • D. System Manager

Answer: A

 

NEW QUESTION 46
To install your VEM, what is the extension of the VEM file name you'll be looking for to complete this install?

  • A. .vib
  • B. .vsm
  • C. .vem
  • D. .zip

Answer: A

 

NEW QUESTION 47
An administrator has a FlexPod solution for use with a VMware vSphere 6.0 environment. The virtual environment consists of virtual machines running both Windows Server 2012 R2 and Windows Server 2008.
The administrator determines that the Windows Server 2008 virtual machine VMDKs are misaligned. The problem needs to be solved without incurring downtime on the virtual machines.
Which tool enables the administrator to solve the problem without virtual machine downtime?

  • A. NetApp mbralign toolkit
  • B. NetApp Virtual Storage Console
  • C. VMware vRealize Operations
  • D. UCS Central

Answer: A

 

NEW QUESTION 48
Which two are required for single-wire management for Cisco UCS C-Series? (Choose two)

  • A. 10 GB LOM
  • B. FI 6200 family only
  • C. VIC 1240
  • D. Redundant Nexus 2232PP FEX
  • E. VIC 1225
  • F. UCS Manager 2.1 or higher

Answer: E,F

 

NEW QUESTION 49
You are installing a FlexPod Express solution with a NetApp AFF A250 at a customer's remote site.
In this scenario, which two devices are required to provide an NFS v3 datastore? (Choose two.)

  • A. Cisco Nexus 3000 Switches
  • B. NetApp BES-53248 Switches
  • C. Cisco UCS 6324 Fabric Interconnects
  • D. Cisco UCS 6454 Fabric Interconnects

Answer: A,C

 

NEW QUESTION 50
Exhibit:

Referring to the exhibit, which two diagrams show the correct way to cable a new NetApp clustered Data ONTAP cluster with two nodes? (Choose two.)

  • A. II
  • B. I
  • C. IV
  • D. III

Answer: A,D

 

NEW QUESTION 51
Which is a valid connectivity option for a FlexPod?
Note some of these may also be 'valid' options outside of a FlexPod architecture but do not specifically meet FlexPod scalability and availability requirements.

  • A. UCS C-Series direct attach FAS
  • B. UCS B-Series > 2232PP FEX > UCS FI > Nexus 5548 < FAS
  • C. UCS C-Series > 2232PP FEX > UCS FI > Nexus 5548 < FAS
  • D. UCS B-Series direct attach FAS
  • E. UCS C-Series > Nexus 3048 < FAS
  • F. UCS B-series > UCS FI > 2232PP FEX > Nexus 5548 < FAS
  • G. UCS B-Series > UCS FI > Catalyst 3750 < FAS

Answer: C,E

 

NEW QUESTION 52
Which two are characteristics of a Fibre Channel SAN data LIF? (Choose two.)

  • A. It can be associated with an IP address.
  • B. It can be associated with an Ethernet port or VLAN interface.
  • C. It can be associated with an interface group (ifgrp).
  • D. It is associated with the management LIF.
  • E. It can be associated with a WWPN.
  • F. It can be associated with a Fibre Channel port.
  • G. It is associated with the administrative Vserver.

Answer: E,F

 

NEW QUESTION 53
Click the Exhibit button.

On your NetApp storage system, you create a volume named datastore1, mount it to a junction path, and then set the correct export policy. When you attempt to mount the volume from VMware ESXi as a datastore, the server is unable to mount the path /datastore1. You verify that your existing NFS datastore (/datastore0) on the same NetApp storage system SVMis functioning normally.
Referring to the exhibit, what is preventing the server from mounting the new datastore?

  • A. The volume is too large to be mounted as an NFS datastore
  • B. The LIF needs to be at its home-port when the volume is mounted.
  • C. The load-sharing mirrors need to be updated.
  • D. Two volumes cannot be mounted using the same LIF IP address.

Answer: C

 

NEW QUESTION 54
When connecting the Nexus 1110-X to the Nexus switch, what Spanning Tree port type is used?

  • A. Edge
  • B. Network
  • C. Edge trunk
  • D. Normal
  • E. Trunk

Answer: C

 

NEW QUESTION 55
Which sends support summary information to NetApp through HTTPS?

  • A. TechSupport
  • B. AutoSupport
  • C. FlexSupport
  • D. SnapSupport

Answer: B

 

NEW QUESTION 56
You have a two-node NetApp clustered Data ONTAP storage system, a Cisco UCS system with two Fabric Interconnects, and a dual-fabric (Fabric-A and Fabric-B) Fibre Channel topology with the information shown below.
- Node 01 has one 10Gb FCoE connection to Fabric-A and one 10Gb FCoE connection to Fabric-B.
- Node 02 has one 10Gb FCoE connection to Fabric-A and one 10Gb FCoE connection to Fabric-B.
- Fabric Interconnect A has a two-port FCoE port channel to Fabric-A
- Fabric Interconnect B has a two-port FCoE port channel to Fabric-B.
- Each IOM in the Cisco UCS blade chassis has four uplinks into the Fabric Interconnects.
- A service profile running VMware ESXi has one vHBA in Fabric-A and one vHBA in Fabric-B.
How many paths should ESXi see to its FC boot LUN?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

 

NEW QUESTION 57
Where are log files located on a NetApp node?

  • A. /etc/mlog/
  • B. /log/core/
  • C. /mroot/etc/log/mlog/
  • D. /mroot/etc/crash/
  • E. /letc/log/crash

Answer: C

 

NEW QUESTION 58
Which two operating modes are available with the Nexus 9000 Series switches? (Choose two.)

  • A. Cisco ACI
  • B. Cisco IOS
  • C. Cisco IOS EX
  • D. Cisco NX-OS

Answer: A,D

 

NEW QUESTION 59
Given the following switch output, where would you expect see notification level messages?
N5K-1# show logging info.
Logging console: enabled (Severity: error)
Logging monitor: enabled (Severity: informational)
Logging linecard: enabled (Severity: emergency)
Logging fex: enabled (Severity: notifications)
Logging time stamp: seconds
Logging server: disabled
Logging logfile: enabled

  • A. Notification messages will not be seen anywhere
  • B. On the linecard
  • C. On the terminal sessions
  • D. On the console

Answer: C

 

NEW QUESTION 60
For a 'boot from SAN' configuration, which two features must be enabled? (Choose two)

  • A. FCOE
  • B. FC
  • C. NPIV
  • D. VPC
  • E. UDLD
  • F. FCSP

Answer: A,C

 

NEW QUESTION 61
Which LIF role is used for SnapMirror traffic on a system running clustered Data ONTAP?

  • A. intercluster
  • B. node-management
  • C. interconnect
  • D. cluster-management

Answer: A

 

NEW QUESTION 62
Your primary VSM needs to be edited, rebooted, or migrated. You need to initiate a manual switchover to your standby VSM.
What command will allow this to occur?

  • A. vsm switchover
  • B. Standby activate
  • C. System switchover
  • D. System standby

Answer: C

 

NEW QUESTION 63
How are jumbo frames enabled on the Nexus 5548?

  • A. system qosmtu 9216
  • B. system mtu jumbo 9000
  • C. system jumbo-frame
  • D. policy-map type network-qos JUMBOclass type network-qos class-defaultmtu 9216system qosservice-policy type network-qos JUMBO
  • E. policy-map type queueingclass type queueing class-defaultmtu 9216

Answer: D

 

NEW QUESTION 64
Which three are types of Storage Virtual Machines? (Choose three.)

  • A. flex
  • B. intercluster
  • C. node
  • D. vFiler
  • E. data
  • F. cluster

Answer: C,E,F

 

NEW QUESTION 65
Exhibit:

You have a NetApp cluster and have just performed a storage failover giveback command from the CLI.
Referring to the exhibit, what is the status of the storage failover process?

  • A. The giveback is partially completed waiting for node cluster-01 to give back the partner's SFO aggregate.
  • B. The giveback failed because cluster-01 was not able to communicate with the partner's cluster LIFs.
  • C. The giveback is partially completed waiting for node cluster-02 to give back the partner's SFO aggregate.
  • D. The giveback failed because the partner node was not in a "waiting for "giveback" state.

Answer: C

 

NEW QUESTION 66
Which two features allow multiple fabric logins through a single port? (Choose two.)

  • A. LLDP
  • B. NPIV
  • C. NPV
  • D. vPC

Answer: B,C

 

NEW QUESTION 67
When configuring a volume to contain a LUN, which administrative tool automatically applies NetApp recommendations?

  • A. Microsoft SystemCenter
  • B. Data ONTAP command-line interface
  • C. VMware vSphere
  • D. OnCommand System Manager

Answer: D

 

NEW QUESTION 68
Your customer needs a new Nexus switch that can support at least ten 40GbE ports, and has room for future growth. Your customer would also like the new switch to be Application Centric Infrastructure- ready.
Which switch meets these requirements?

  • A. Nexus 5672
  • B. Nexus 9504
  • C. Nexus 7004
  • D. Nexus 6004

Answer: B

 

NEW QUESTION 69
......

Reduce Your Chance of Failure in NS0-176 Exam: https://www.itexamreview.com/NS0-176-exam-dumps.html